Humidity
Test: Performed for 90 % Humidity
at 55 C for a Single Cycle of 24 Hours. After the
test Micro VBB found no abnormalities |
 |
High
Temperature Test:
Micro VBB undergone High temperature test at
+85 C +/- 2 C for 4 hours and it was found functional
when it comes to 55 C +/- 2C. It has not shown any
abnormalities after the test conditions were removed.
Storage Temperature: +85 C,Operating Temperature:+55
C |
 |
Low
Temperature Test: Low temperature
test were conducted at –40 C for four hours
and it was found functional when the temperature comes
down to –10 C
Storage Temperature:-40 C,Operating Temperature:-10
C |
 |
Electro
Static Discharge Test: The Micro VBB
with stand Electro Static Discharge up to 1500 V with
6 Events both positive and negative pulses applied
to Micro VBB. This is according to standard CI-280A,
B of Ford Motor Company |
 |
Component
Immunity Power Cycling: According
to the Standard CI – 230 A, CI – 230 B,
CI – 230 C in the standard test environment
Micro VBB was tested and it was functioning properly
|
 |
Component
Conductive Immunity: According to
the Standard CI – 210A1, CI – 210A2, CI
– 210B1,CI-210B2 in the standard test environment
Micro VBB was tested and it was functioning properly.
|
 |
DC
Voltage Stress: Micro VBB withstand
the negative voltage Stress of –14 V for 60
Sec accordance to Standard CI-270 A. It also underwent
positive voltage stress of 19 V for 60 minutes. Standard
CI-270B. In Accordance to CI-270C standard Micro VBB
withstand up to 24 V DC for 60 Sec.
Conducted Immunity Inductive Switching Transients:
Micro VBB is tested for Ford Inductive Switching CI-220B
–300V at 0.5 Sec interval and the Total test
events was 120.
IS0 7637 Modified test pulse –2 : +150V at 0.5
Sec intervals for 120 Events
IS0 7637 Test pulse 3A: -150V at total time duration
of One Minute with pulse of 10 mSec duration at interval
of 90 mSec between the consecutive pulses.
ISO 7637 Test Pulse 3B: 100V Pulse of 10mSec duration
with 90 mSec intervals for total time duration of
1 minute.
In these conditions Micro VBB gave Positive results
|